juan carlos diaz martin (jdiaz@mx3.redestb.es) wrote:
: Do I need a Real Time Operating System -such as POSIX.4- under Ada95 in
: order Ada95 programs using the Real Time Anex behave in the predecible
: way the programmer expect? Or Posix.1 + Ada95 is enough?
: Comments and bibliografic references would br appreciated.
The compiler vendor has to validate using a combination of a compiler
and a run-time system. You shouldn't need to select your own
RTOS, and you probably can't expect a given Ada compiler to integrate
direclty with an arbitrary RTOS. Instead, you should select which
validated compiler/RTOS combination meets your needs, by surveying the
Ada 95 compiler vendors who support the RT annex
(alphabetically: ACT, Aonix, Concurrent, DDC-I, Green Hills, ICS, OCS,
Rational, RR, TLD, ...).
--
-Tucker Taft stt@inmet.com http://www.inmet.com/~stt/