From: Vernon Brown <brownv@az.honeywell.com>
Subject: Record Rep specs, endian: big -> little, Storage_Unit: 8 -> 16
Date: 1996/10/17
Date: 1996-10-17T00:00:00+00:00 [thread overview]
Message-ID: <32665D2C.20431CA7@az.honeywell.com> (raw)
I am porting a large avionics application from a big-endian processor,
AMD-29050, to a little endian processor, Intel-P5. The compiler for the
29050 has a System.Storage_Unit of 8 bits, but the compiler I'm using
for the port to Intel has a Storage_Unit of 16 bits.
The application has many record rep specs that map onto external byte
streams of data. Is there any chance that I can write rep specs that
will work in both environments, and if not, what rules could I apply
when modifying the rep specs?
An example record rep spec is:
for Leg_Fault_Record_Type use record
Time_First at 0 range 0 .. 15;
Flight_Phase at 2 range 0 .. 7;
System_Mode at 3 range 0 .. 7;
Test_ID at 4 range 0 .. 7;
Fault_ID at 5 range 0 .. 15;
Fault_Type at 7 range 0 .. 7;
Intermittent_Count at 8 range 0 .. 7;
Time_Recent at 9 range 0 .. 15;
Isolation_Data at 11 range 0 .. 127;
Detail_Data_Indicator at 27 range 0 .. 7;
Reserved at 28 range 0 .. 31;
end record;
Please email me as well as posting to the news group, as my news reader
sometimes gets behind by 3 or 4 days.
--
Vernon Brown X6-3057 email: brownv@AZ.Honeywell.com