Dave Emery was looking for a way to write a "terminate but stay
resident" interrupt handler in Ada. Actually, the rules of Ada make
this straightforward, given appropriate implementation support. The key
is to declare the interrupt-handler task not in the main program, but in
a library package:
PACKAGE Interrupt_Handler_Package IS
TASK Interrupt_Handler IS
ENTRY Interrupt_Entry;
FOR Interrupt_Entry USE AT ...;
END Interrupt_Handler;
END Interrupt_Handler_Package;
PACKAGE BODY Interrupt_Handler_Package IS
TASK BODY Interrupt_Handler IS
...
BEGIN
LOOP
ACCEPT Interrupt_Entry;
... -- Service the interrupt
END LOOP;
END Interrupt_Handler;
END Interrupt_Handler_Package;
WITH Interrupt_Handler_Package;
PRAGMA Stay_Resident (Interrupt_Handler_Package);
-- Hypothetical implementation-defined pragma (see text below)
PROCEDURE Install_Handler IS
...
BEGIN
NULL; -- Alternatively, as Dave Emery put it, "Do something for a
-- while, then finish up."
END Install_Handler;
The library package Interrupt_Handler_Package is elaborated, thus
activating the Interrupt_Handler task, before the main program
Install_Handler begins execution. Then the note in paragraph 9.14(13)
of the Reference Manual comes into play:
On the other hand, termination of the main program does not
await termination of tasks that depend on library packages;
the language does not define whether such tasks are required
to terminate.
Thus the main program terminates. Under an implementation in which all
Ada tasks are interleaved in a single operating-system task, the
Interrupt_Handler task would probably also terminate at this point; but
under a system supporting the terminate-but-stay-resident concept, the
Interrupt_Handler task could continue to execute.
The example above supposes an implementation-defined pragma to tell the
run-time system to keep resident all tasks in a given library package,
but an implementation could conceivably do this by default. An
implementation could also conceivably restrict the stay-resident
semantics to tasks whose bodies have a particular structure--for
example, a single loop beginning with a simple accept statement for an
interrupt entry, since such a task could be made to "continue executing"
simply by installing an interrupt handler, with no need to maintain task
control blocks or perform explicit scheduling.
Since we want the Interrupt_Handler task to execute forever, its body
does not contain a terminate alternative. Indeed, a terminate
alternative in a task dependent on a library package is always useless
because it cannot be selected. See RM paragraph 9.4(8).
^ permalink raw reply [flat|nested] only message in thread
only message in thread, other threads:[~1987-11-14 22:50 UTC | newest]
Thread overview: (only message) (download: mbox.gz / follow: Atom feed)
-- links below jump to the message on this page --
1987-11-14 22:50 "Terminate but stay resident" interrupt handlers Norman COHEN
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox