From mboxrd@z Thu Jan 1 00:00:00 1970 X-Spam-Checker-Version: SpamAssassin 3.4.4 (2020-01-24) on polar.synack.me X-Spam-Level: X-Spam-Status: No, score=-1.3 required=5.0 tests=BAYES_00,INVALID_MSGID autolearn=no autolearn_force=no version=3.4.4 X-Google-Language: ENGLISH,ASCII-7-bit X-Google-Thread: 103376,29fe9a340e0d180d X-Google-Attributes: gid103376,public From: Simon Wright Subject: Re: Depending on passing mechanism Date: 1997/10/22 Message-ID: #1/1 X-Deja-AN: 282480717 References: X-NNTP-Posting-Host: pogner.demon.co.uk [158.152.70.98] Organization: At Home Newsgroups: comp.lang.ada Date: 1997-10-22T00:00:00+00:00 List-Id: mheaney@ni.net (Matthew Heaney) writes: > type Temperature_As_Record is > record > Temperature : Temperature_in_Celsius_Base; > end record; > > for Temperature_As_Record use > record > Temperature at 0 range 7 .. 15; > end record; I guess I would have put this part at least inside the function and included something about System.Default_Bit_Order .. if System."=" (System.Default_Bit_Order, System.Low_Order_First) then declare type Little_Endian_Temperature_As_Record is new Temperature_As_Record; for Little_Endian_Temperature_As_Record use record Temperature at 0 range 0 .. 8; end record; for Little_Endian_Temperature_As_Record'Size use ... function Convert is new Unchecked_Conversion (..., Little_Endian_Temperature_As_Record); begin Result := Temperature_As_Record (Convert (...)); end; else ... -- Simon Wright Work Email: simon.j.wright@gecm.com GEC-Marconi Radar & Defence Systems Voice: +44(0)1705-701778 Command & Information Systems Division FAX: +44(0)1705-701800